Dual 1X6 AES/EBU Digital Audio DA, Re-clocked, full featured including display - 110 ohm XLR I/O

1.389,90 € HT
1.662,32 € TTC
Catégorie : Distributeurs
Marque : ATIAUDIO
Référence : DDA212-XLR
DDA212-XLR model use XLR connectors and operate from and drive a 110-ohm balanced shielded twisted pair distribution system per AES3-1992.
Disponibilité : 2 semaines
 
  • Accepts sample rates from 27 to 96kHz
  • Displays standard sample rates of 32, 44.1, 48, 88.2, 96 kHz (DDA only)
  • Status and error LEDs show clock lock and data validity (DDA only)
  • Adjustable input equalizers compensate for very long cable runs (DDA only)
  • Data is relocked and regenerated before low-jitter transmission (DDA only)
  • Loop thru transformer balanced and isolated inputs
  • Switchable input termination resistors
  • Individual, transformer balanced and isolated 110 ohm XLR outputs (-XLR only)
  • Single or dual inputs
  • Up to 12 XLR
  • Quiet, internal linear power supplies
  • Attractive, 1RU package
INPUTS:
Connectors: XLR female or BNC, DC isolated from chassis.
Input connector pairs paralleled for loop-thru.
Level: 200mVp-p minimum
Impedance: Transformer isolated, capacitor coupled, balanced and floating, XLR inputs 110 ohms, and BNC and RCA inputs 75 ohms.
Terminating resistors may be switched in or out on rear panel.
Cable Length: 300m of 110-ohm cable, 1000 m of 75 ohm coax (with equalizer)
Equalizer: Multi-turn panel control, adjust using DSA panel indicators
Sample Rates: Accepts 27kHz to >100kHz
DDA Clock: Regenerated from input signal with dual-mode PLL Clock
Jitter <3nanoseconds peak-to-peak at 96kHz sample rate
DSA Clock: Non-regenerated. Input clock is passed directly to outputs.
OUTPUTS:
Connectors: XLR male, 6 or 12; BNC chassis mount, 12 or 24
Levels: XLR, 4Vp-p loaded at 110 ohms. BNC, 2Vp-p loaded at 75 ohms, RCA, 0.5Vp-p loaded at 75 ohms
Impedances: XLR: 110 ohms, balanced, transformer isolated and capacitor coupled
BNC: 75 ohms, unbalanced, capacitor coupled
Output Jitter: <3 nanoseconds peak to peak at 96kHz sample rate
Output Delay: Three frames (sample intervals) at the sample rate